AbstractAerators are applied to provide air entrainment and cavitation erosion protections for high-speed flows. By traditional chute aerators in high-head bottom tunnels, it is difficult to maintain effective aeration protection for low-Froude-number and small-slope conditions. The present study explores a wedge aerator design at the bottom outlet, and detailed experimental data on the aeration cavity and the entrained air diffusion were obtained to assess the aeration protection performance. The wedge aerator separates the water flow from the bottom outlet into an upper free jet and a lower flow layer, creating a middle aeration cavity. The flowing lower layer can enhance the aeration cavity stability, ensuring the cross-sectional air diffusion generation downstream due to the flow collision interactions. The flow Froude number and vertical location are the main parameters affecting the air entrainment coefficient, cross-sectional air concentration distribution, and sufficient concentrations close to the chute floor. Optimized wedge aerators are proposed, indicating that the flow interior separation is an effective hydraulic design for bottom outlets in hydraulic engineering.IntroductionBottom tunnels to evacuate floods are a typical element of high-head dams. They consist of a pressurized conduit that connects an upstream reservoir to an open channel via a pressure gate that transforms the pressured flow into a free-surface flow. For water heads of 100–200 m, the velocity of the flow from the pressurized tunnel outlet into the open channel can reach 30–40 m/s. Bottom outlets operating under high-velocity flows can cause cavitation erosion. A prototype bottom tunnel after a flood discharge operation is shown in Fig. 1; there is severe cavitation erosion on the sidewalls close to a radial gate, and the damaged area extends clearly downstream.Previously, aerator devices were the most effective way of controlling cavitation erosion (Peterka 1953; Rasmussen 1956; Russell and Sheehan 1974). However, if the chute connected to the bottom outlet usually has a small slope, the flow rollers rear of the air entrainment cavity retrogress and cause air duct choking, resulting in dangerous local cavitation damage. This makes it difficult to achieve adequate aeration protection using typical chute aerators (e.g., deflector or offset) located near the flat bottom outlet. Therefore, further research into the design of aerators for bottom outlets is required to improve gate outflow and flow aeration so that cavitation damage can be avoided.A typical aerator consists of several transverse and vertical grooves around the chute walls that are connected to an air supply. Air is entrained into the water flow through the air cavity neighboring the water flow surface owing to the difference in atmospheric pressure. The cavity jet length, air entrainment coefficient, and air diffusion evolution near the wall are the main parameters used to describe the aerator efficiency. For bottom aerators, Pfister and Hager (2010a, b) investigated the optimum design parameters for an aerator, including the approach flow Froude number, deflector angle, and chute floor slope. Limits on the Froude number Fr0 were suggested to be Fr0=6 for bottom offsets and Fr0=4–5 for bottom deflectors with deflector angle α=6–11. Steep chutes with a floor slope φ>30° were more efficient than those with a small slope, and these limits were reduced for steep chutes. Under adverse conditions such as low-Froude-numbers and small-chute slopes, the water jets flowing over the aerator are poorly aerated, and the water rollers on the floor of the chute move conversely to the air supply devices, filling the jet cavity (Laali and Michel 1984; Rutschmann and Hager 1990; Shi et al. 1983; Qian et al. 2014).The mechanism reason for the cavity filling was deduced that the aerator geometry and flow conditions could lead to a high cavity subpressure, acting as the onset of the filling cavity. By summarizing prototype and model aerator performances (Chanson 1995), flow choking phenomena of chute aerator cavities were obvious for Fr0<4 and φ<12°, and a minimum value of Fr0=7–8 was proposed with a critical ratio of flow depth to offset height. Thus, the research gap in the aerator device for flat tunnels remains open, and the relevant flow pattern generating an effective air entrainment near the bottom outlet should be explored to advance the knowledge and technology.In addition, as water flows with large depths release from a bottom aerator, neither free surface nor bottom cavity air entrainment can make the air diffuse immediately across the full flow section. The unaerated region in the center of the high-speed flow puts the sidewall at risk because the bottom aerator does not provide sufficient protection. To promote aerator applications, lateral deflectors or offsets combined with bottom devices have been designed. To optimize lateral aerators, the lateral cavity length should be less than the bottom cavity length; otherwise, unstable shock waves from the reattachment area between the lateral jet and the sidewalls can plug the air entrainment path and reduce the protection against cavitation erosion, as shown in Fig. 2.Flat chutes have a relatively short bottom cavity, so it is difficult to obtain good aerated flow patterns downstream (Li et al. 2011; Wu et al. 2013; Xu et al. 2020). The flow pattern over the sidewall aerator is impressible for lateral deflector design parameters (Liu et al. 2007; Wang et al. 2006). Li et al. (2016) studied the evolution of sidewall pressure along the side cavity of a lateral aerator in a radial gate. Their results indicated that the sidewall pressure decreased as the radial gate operated, which could raise cavitation erosion risks of the sidewalls. These effects should be fully considered for full-section aeration and cavitation erosion protection on prototype bottom tunnels (Liu et al. 2006; Liu 2006). Thus, it is still necessary to design an appropriate aerator device for practical applications that can eliminate cavitation erosion for chutes with small slopes and bottom outlet sections.For the design case of bottom outlets, the present study proposes a wedge aerator at the radial outlet connected to a flat chute. A series of hydraulic model tests were conducted to investigate the air entrainment and aerated flow features downstream from the wedge aerator, including the air diffusion and transport processes. Compared with the air entrainment generation of the wedge aerator with traditional aerators, the specific flow pattern for air–water flow is clarified to understand the mechanisms of the air diffusion process in bottom-outlet structures. Based on the aeration cavity and downstream air diffusion performances, the optimal height location for the wedge aerator is also discussed. These findings will help engineers designing bottom outlet and tunnel structures, improving the aeration protection for high-speed chute flows in high-head dams.Experimental SetupExperiments to examine the wedge aerator and corresponding air–water properties (Fig. 3) were conducted using a 0.25-m-wide rectangular chute model at the State Key Laboratory of Hydraulics and Mountain River Engineering, Sichuan University, China. A typical bottom outlet with a radial gate was connected to an 8-m-long open channel. The widths of the bottom outlet and open channel were identical. The chute had a constant slope of α=3° relative to the horizontal direction. Water flows were released from a pressurized outlet with a constant outlet height of h0=0.23 m. Approach Froude numbers of Fr0=V0/(gh0)0.5 were generated with various water discharge conditions, where V0 is the average flow velocity at the bottom outlet and g is the gravitational acceleration.The velocity was given by V0=qw/(h0−t), where qw is the discharge per unit width, and t was the height of the wedge aerator. The water discharge Qw was supplied by a water circulation system. Seven flow discharges were tested, and V0 ranged from 2.7 to 4.2 m/s with Fr0 between 1.8 and 2.9. Thus, tests were conducted with low Froude numbers and small chute slope conditions. The x-axis was defined as the streamwise direction along the chute floor, starting at the roof of the bottom outlet. The y-axis was perpendicular to x, starting at x=0.For supercritical air–water flows in open channels, the scale effects of air–water properties relating to the hydraulic model were hard to avoid, and it was difficult to obtain similarity of air–water mixture properties from scale-physical models (Felder and Chanson 2017). To minimize scale effects of the air concentration of aerated open channel flows, limitations relative the approach flow Reynolds number Re0=V0h0/ν and Weber number We0=(ρV02h0/σ)0.5 are suggested as 1.0×105 and 140, respectively, where ρ is the water density, σ is the surface tension, and ν is the kinematic water viscosity (Pfister and Hager 2010a; Pfister and Chanson 2014; Heller 2011). In the present model tests, the limitations due to scale effects were respected with minimum values of Re0=4.7×105 and We0=150. Although experimental tests were carried out considering the scale limitations of the air–water flow, scaled models are prone to scale effects in the aeration properties (Falvey and Ervine 1988; Chanson 1996). The measurements paid particular attention to the air diffusion properties and were used to analyze the aeration efficiency of the wedge aerator.The wedge aerator was set between the roof and the floor of the pressurized outlet. Smooth curves were used for the upper and lower solid walls, and an inclined side was used to fit the bottom outlet and radial gate configurations, as shown in Fig. 4. The length L of the wedge aerator was 31.5 cm, and the vertical height t was 4.5 cm. The inclined sides contained several air holes, which connected the aeration and air supply systems.The approach water passing through the wedge aerator was divided into upper and lower flows with depths of h1 and h2, respectively. The upper flow acted as a jet with two free surfaces, and the lower flow moved along the open channel. An aeration cavity was generated between the flows, and the air entrained by the wedge aerator was supplied via two lateral dropshafts on each side. The upper and lower flows reattached downstream at the end of the aeration cavity, and the impact interaction between them entrained air into the water, creating the cross-sectional air–water mixture. Air diffused to the floor and the free surface simultaneously. Air bubbles reaching the bottom floor and sidewalls could provide aeration protection. Moreover, the movement of the lower flow prevented the backwater from choking the aeration cavity and guaranteed free air flow below the upper flow. Furthermore, the angles between the upper and lower flows were small, which avoided splashing water and uncertain shock waves, and the free surface remained smooth because the air–water flow developed downstream.The ratio e=h2/h0 was used to represent the relative position above the floor. To obtain the optimal vertical location of the wedge aerator, six wedge aerator locations were arranged from 0.04 to 0.43 based on the entrained air diffusion performance close to the chute floor, and the maximum h2=10 cm. It was possible to control the two flows independently by changing e, and different V0 values could be tested with the same e. Thus, the effects of different Fr1 and Fr2 on wedge aerator performances were obtained for identical V0 conditions.Several specific parameters for the air entrainment and downstream air diffusion were selected for the wedge aerator performance analyses. The aeration cavity length La was visually detected as the distance between x=0 and the reattachment point of the two flows. The cross-sectional air concentration distribution C(y) of the flow was measured using a phase-detection needle probe (CQY-Z8a Measurement Instrument, Institute of Water Resources and Hydropower Research, Beijing). The principle of the resistance-type probe was to determine the air concentration by detecting the clear water resistance and the aerated water resistance between the two electrodes. The sampling period for each measurement point was set to 120 s with a 100-Hz frequency. The time-averaged air concentration was calculated from the integration time, and the measurement accuracy was ±10% if the sampling period exceeded 60 s.For each test condition, approximately 120 air concentration measurement points were obtained at eight cross-sections. The first point was set 5 mm above the floor to obtain the bottom air concentration Cb. The air entrainment coefficient β was used to describe the aeration capacity of the wedge aerator. It was defined as β=Qa/Qw, where Qa is the air quantity deduced from the first section close to the attachment point, which does not account for air entrainment along the upper free surface by the upper flow.Results and DiscussionCavity Characteristics of a Wedge AeratorThe typical flow patterns of two wedge aerator designs are shown in Fig. 5. Along the approach flow direction, the wedge aerators deflected the water and produced a free jet above a flow moving forward along the open channel. The thickness of the aeration cavity between the two flows gradually decreased in the streamwise direction. The upper jet reattached to the lower flow at a certain reattachment location, which generated a considerable layer of air–water mixture in the middle of the combined flow. The flow downstream from the reattachment section was fully aerated as a typical air–water flow.The effects of wedge aerator vertical positions for different Fr0 conditions were observed in the cavity areas. For e=0.04 with a low Fr0=1.8, unstable flow rollers were observed and the cavity was partially choked. The recirculating water could fill back to the wedge aerator intermittently. For a large e=0.43 with identical Fr0=1.8, a longer cavity was observed due to the cast capacity improvement of the upper jet flow; moreover, the partially choking phenomenon got weakened. As the approach Fr0 increased to 2.9, the aeration cavity became stable, ensuring an effective cavity length. Besides, the aeration cavity became more stable with increasing e, but air diffusion toward the chute floor was weak and there was a layer of unaerated water closed to the bottom floor downstream. Thus, the lower flow layer played a key role in stabilizing the aeration cavity and simultaneously restricted the fully cross-sectional air diffusion. Both of the aeration effects should be considered for the wedge aerator design to avoid insufficient air entrainment and low air concentration because these might provoke local cavitation erosion damage.The air entrainment cavity length between the wedge aerator and the reattachment point La was used as a characteristic parameter of the two separated flows. The values of La/t are plotted in Fig. 6(a). As the approach e increased, the cavity length increased for all of the tested Fr0 values. According to the cavity-generation mechanism, the cavity length is determined by the upper-flow ejection combined with its reattachment interaction with the lower flow. Thus, the upper-flow Froude number Fr1=V0/(gh1)0.5 is an essential factor. Two effects govern Fr1: (1) the water-head energy represented by V0; and (2) the relative flow proportion, dependent on the position of the wedge aerator. The cavity length can be expressed as an approximately linear relationship La/t=2.25·(Fr1−1) with R2=0.869, as shown in Fig. 6(b).In contrast to other chute aerators, including deflectors and offsets, there is a flow layer below the aeration cavity. When this lower flow layer is thin (e<0.1), Fig. 6(c) shows that the cavity length with a wedge aerator La will be shorter than that with other aerators Lcal, as calculated by Pfister and Hager (2010a). This is mainly because the thin lower flow is insufficient to stabilize the cavity, and the choking effect caused by a small chute slope is unavoidable. Even for a low location with e=0.04, the aeration cavity does not disappear and La/Lcal remains at approximately 0.6–0.8. As the lower flow layer increases with e=0.1–0.2, La/Lcal is approximate 0.8–1.0, which indicates that the wedge aerator cavity with small Fr0 and flat chute conditions is as effective as traditional aerator cavities. For a relatively thick flow (e>0.2–0.3), La increases gradually, reaching approximate 1.2 times of Lcal for e=0.4–0.5. This indicates that the thick lower flow can maintain the air entrainment efficiency of the wedge aerator.The effects of e and Fr1 on the air entrainment coefficient β are shown in Fig. 7. As Fr1 increases, β gradually increases, which can be expressed as linear relations for different e conditions. Compared with the conditions e<0.1 and 0.3
Source link